HP Checklist for Contractor Installers
This checklist presents what CEC expects for all HP installs for BPA/CEC incentive.
Outdoor Unit
- Prepared ground surface that is flat and level
- Install pad or pad blocks
- Use risers or riser blocks
- Anchor unit to risers
- Avoid installing outdoor unit on deck or near pathway
Line Set
- Insulate entire line set length (Best Practice is to insulate the fittings also)
- Protect outdoor line set with line hide or cover with a UV protective material
- Seal penetrations through the shell with insulative sealant
Condensate Line
- Must slope downhill
- Must exit the shell
- Output should avoid walkways and decks
Indoor Unit(s)
- Level
- Explain controller
- Explain filter cleaning/maintenance
Required Photographs
- Photograph of the front outdoor unit, showing pad, risers, and level unit
- Photograph of outdoor unit manufacturer’s label
- Photograph of each indoor unit installed showing placement in room(s) (if applicable)
- Photograph of each indoor unit’s manufacturer’s label
- Photograph of each condensate line termination
- Photograph of insulated line set
- Photograph of exterior line set house penetrations
- Photograph of backup heating lockout setting at 35 degrees